This file is raw output from pdftotext and may not be ideal for distribution. If you are a maintainer for Hackipedia, please sit down when you have time and clean this text version up. Source PDF: /mnt/main/jmc-storage/docs/SCTE/ANSI SCTE 014 Test Method for Hex Crimp Tool Verification & Calibration (2011).pdf Like all conversions the text below should be fully readable as UTF-8 unicode text. --------------------------------------------------------------- ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 14 2011 Test Method for Hex Crimp Tool Verification/Calibration NOTICE The Society of Cable Telecommunications Engineers (SCTE) Standards are intended to serve the public interest by providing specifications, test methods and procedures that promote uniformity of product, interchangeability and ultimately the long term reliability of broadband communications facilities. These documents shall not in any way preclude any member or nonmember of SCTE from manufacturing or selling products not conforming to such documents, nor shall the existence of such standards preclude their voluntary use by those other than SCTE members, whether used domestically or internationally. SCTE assumes no obligations or liability whatsoever to any party who may adopt the Standards. Such adopting party assumes all risks associated with adoption of these Standards or Recommended Practices, and accepts full responsibility for any damage and/or claims arising from the adoption of such Standards or Recommended Practices. Attention is called to the possibility that implementation of this standard may require use of subject matter covered by patent rights. By publication of this standard, no position is taken with respect to the existence or validity of any patent rights in connection therewith. SCTE shall not be responsible for identifying patent for which a license may be required or for conducting inquires into the legal validity or scope of those patents that are brought to its attention. All Rights Reserved © Society of Cable Telecommunications Engineers, Inc. 2011 140 Philips Road Exton, PA 19341 i TABLE OF CONTENTS SECTION TITLE PAGE NOTICE i TABLE OF CONTENTS ii 1.0 SCOPE 1 2.0 EQUIPMENT 1 3.0 VERIFICATION OF HEX CRIMP SIZE 1 4.0 CRIMP TOOL ADJUSTMENT METHOD 1 5.0 DOCUMENTATION 2 ii 1.0 SCOPE 1.1 To determine and verify the actual crimp dimension of hex crimp tools. 1.2 Measurement technique for determining the final hex size that may affect pull-off performance of the cable-to-connector interface. 1.3 Calibration technique for adjusting hex crimp tools. 2.0 EQUIPMENT 2.1 Machinist’s outside micrometer having a flat anvil and flat spindle, calibrated to read directly to at least 0.005 inch (0.127 mm), with each division of a width that facilitates estimation of each measurement to 0.0005 inch (0.0127 mm). As an alternate use digital calipers calibrated to read directly to at least 0.0005 inch (0.0127 mm). 3.0 VERIFICATION OF HEX CRIMP SIZE 3.1 Crimp an empty F-fitting (no cable) of the appropriate size in the front- most hex cavity. 3.2 Using a micrometer or digital caliper, measure and record the dimensions across each of the three sets of hex flats. 3.2.1 No single measurement across hex flats should deviate more than  0.005 inch ( 0.127 mm) of the published hex size. 3.3 Average the three measurements recorded in 3.2. 3.3.1 The average hex crimp measurement should be within  0.003 inch (0.076 mm) of the published hex size. 3.4 Repeat procedures 3.1 through 3.3 for each hex cavity. 3.5 If discrepant measurements are obtained, proceed to Section 4, Adjustment Method. 4.0 CRIMP TOOL ADJUSTMENT METHOD 4.1 If crimp tool is adjustable, adjust the tool cam adjustment mechanism per the tool manufacturer’s instructions. Adjustments should be made one notch at a time so that the tool is not over-adjusted or damaged. 1 4.2 Secure the cam keeper, crimp an F-fitting (no cable) and measure the flats as described in Section 3.0. 4.3 Continue the adjusting process until the correct hex specification is measured. 4.4 If correct hex measurements cannot be obtained by adjustment, the crimp tool must be rebuilt or replaced. 5.0 DOCUMENTATION Crimp Tool Manufacturer - Crimp Tool Part Number - F-Fitting Manufacturer - F-Fitting Part Number - Hex Crimp Dimensions Hex Number 1 Hex Number 2 Hex Number 3 a) a) a) b) b) b) c) c) c) Average - Published Hex Dimensions Maximum Difference Average Difference 2